Communication: RS - 485/RS - 232, can be connected to Gasboard series smoke analysis equipment
Power Supply: 100 - 240VAC, 80W
Measured Components: H₂S, O₂, CO, CO₂, CH₄
Measurement Principle: TDLAS
Applicable Media: Non - combustible gases such as air, flue gas, etc.
Applicable Pipeline Diameter: ≥ 0.5m
Applicable Engine Range: Engines of any size, at any speed, and with exhaust pipes of various specifications
Sampling Flow Measurement Accuracy: ≤ ±4% (Dilution ratio ≤ 15:1)
Measurement range detection range: 100mm - 3000mm
Pressure bearing: 0 - 1Mpa
Supply voltage (VDC): 9~36V (test voltage: 12V)
Supply current (mA): <30
Detection Principle: Non - Dispersive Infrared (NDIR) Detection Technology
Detected Gas Types: Electrolyte vapors such as DMC, EMC, EC
Detected Gases: PM2.5, CO₂
Technical Principle: PM2.5: Laser scattering;CO₂: Single - light - source NDIR, dual - channel
Measurement Components: H2, N2, O2, CO, CO2, CH4, C2H2, C2H4, C2H6, C3H6, C3H8, H2S
Measurement Range: 0 - 100% (Range can be selected according to on - site conditions)
Technical Principle: Metal Oxide Semiconductor (MOX)
Detection Objects: CO, NO₂, NH₃ (optional)
Detection Range: 400 - 5000ppm (expandable to 40000ppm)
Detection Accuracy: ±(50ppm + 5% of the reading)
Measured Components: CH₄, CO₂, CₙHₘ*, Calorific Value
Measurement Principle: NDIR
Product: Ultrasonic Distance Sensor
Detection Range: 300mm~5000mm
Measuring range: 0.25m~3m (5m customizable)KUS550A; 0.15m-0.6m(1m customizable)KUS550B
Blind spot: The dead zone of KUS550A is 0 ... 250 mm (within 250mm is unstable working zone, it is not recommended to work in this range); the dead zone of KUS550B is 0-150mm;
問い合わせを直接私たちに送ってください.